000193241 001__ 193241
000193241 003__ CZ-ZdVUG
000193241 005__ 20190520102330.0
000193241 041__ $$aeng
000193241 040__ $$aABC039$$bcze
000193241 1001_ $$aPálinkáš, Vojtěch
000193241 24510 $$aOn the effect of distortion and dispersion in fringe signal of the FG5 absolute gravimeters
000193241 300__ $$a14 stran
000193241 500__ $$aRIV: RIV/00025615:_____/16:#0002201
000193241 5203_ $$9eng$$aThe gravity reference, which results from the international comparisons held with the participation of numerous absolute gravimeters, is significantly affected by qualities of instruments prevailing in the comparisons (i.e., at present, FG5 gravimeters).Therefore, it is necessary to thoroughly investigate all instrumental (particularly systematic) errors. This paper deals with systematic errors of the FG5#215 coming from the distorted fringe signal and from the electronic dispersion at several electronic components including cables. In order to investigate these effects, we developed a new experimental system for acquiring and analyzing the data parallel to the FG5 built-in system.
000193241 655_4 $$aanotace
000193241 653_0 $$alaser interferometry$$aabsolute gravimeter
000193241 7730_ $$92016$$g53(1), p.27-40$$tMetrologia$$x0026-1394
000193241 856__ $$uurn:doi:10.1088/0026-1394/53/1/27
000193241 85642 $$uhttps://www.rvvi.cz/riv?s=rozsirene-vyhledavani&ss=detail&n=0&h=RIV%2F00025615%3A_____%2F16%3A%230002201%21RIV16-MSM-00025615
000193241 910__ $$aABC039
000193241 980__ $$aclanky_vugtk
000193241 985__ $$apalinkas
000193241 985__ $$aanotace
000193241 985__ $$ariv
000193241 985__ $$autvar24