Bibliografie VÚGTK
The international DORIS service contribution to ITRF2020
Štěpánek, Petr

Zdroj: Advances in Space Research : 72. (1), s. 65-91 ISSN: 0273-1177

Typ publikace: článek v odborném periodiku
Rozsah: 27 stran

Odkaz: https://www.sciencedirect.com/science/article/pii/S0273117722005865?via%3Dihub
Anotace:
For the realization of the 2020 International Terrestrial Reference Frame (ITRF2020), the International DORIS Service delivered to the International Earth Rotation and Reference Systems Service (IERS) a set of 1456 weekly solution files from 1993.0 to 2021.0 including station coordinates and Earth orientation parameters (EOPs). The data come from fourteen DORIS satellites: TOPEX/Poseidon, SPOT-2, SPOT-3, SPOT-4, SPOT-5, Envisat, Jason-1, Jason-2, Cryosat-2, Saral, HY-2A, Jason-3, Sentinel-3A and Sentinel-3B. In their processing, the four analysis centers which contributed to the DORIS combined solution used the latest time variable gravity models, the new mean pole and diurnal-subdiurnal tidal EOP models recommended by IERS. In addition, all the analysis centers included in their processing precise SPOT-5 solar panel angle values and quaternions for, at least, the Jason satellites. Furthermore, a new Alcatel phase center variation model was implemented for the ITRF2020 processing. The main objective of this study is to present the combination process and to analyze the impact of the new modeling on the performance of the new combined solution. Comparisons with the IDS contribution to ITRF2014 show that i) the application of the new phase center variations for the Alcatel DORIS ground antennas in the data processing combined with the gradual replacement over time of the Alcatel by Starec antennas implies a scale drift from 1993.0 to 2002.5 and ii) thanks to a better modeling of the surface forces on the satellites, the new combined solution shows smaller annual and 118-day signals in the geocenter. A new DORIS terrestrial reference frame was computed to evaluate the intrinsic quality of the new combined solution. That evaluation shows that over almost the full time span the intrinsic IDS scale values lie in a range of 5 mm. After mid-2008, the new DORIS reference frame has an internal position consistency in North-East-Up better than 7.5 mm.

Citace: Štěpánek, Petr. The international DORIS service contribution to ITRF2020. Online. Advances in Space Research. 2022, roč. 72, č. 1, s. 65-91. ISSN 0273-1177. Dostupné z: https://doi.org/10.1016/j.asr.2022.07.012. [cit. 2023-11-23].

Záznam se nachází v těchto sbírkách:
Výsledky VÚGTK > Podle útvarů / oddělení > 24: Geodézie a geodynamika
Výsledky VÚGTK > Vědečtí výzkumníci > Ing. Petr Štěpánek, Ph.D.
Dokumentační centrum VÚGTK > Články VÚGTK
Výsledky VÚGTK > Výsledky RIV
Recenzovaný odborný článek
Anotace článků

 Záznam vytvořen 2023-11-23, poslední editace 2023-11-27


Externí odkaz:
Stáhnout fulltext
Fulltext
Hodnotit tento dokument:

Rate this document:
1
2
3
 
(Ještě nerecenzováno)